ver : a_4 update : 2015.11.27 ac-dc power module ancn series 15 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -1- electrical specifications all specifications valid at normal in put voltage, full load and +25c after warm-up time unless otherwise stated. model no. ( single output ) ancn-5s ancn-12s ancn-15s ANCN-24S max output wattage (w) 15w voltage 90-264 vac or 120-370 vdc frequency (hz) 50 / 60 hz current (full load) 315 ma max. (115 vac) / 195 ma max. (230 vac) inrush current 15 a max. (115 vac) / 30 a max. (230 vac) (cold start) leakage current 0.25 ma max. (at <240 vac) input external fuse (mandatory) 1.5 a slow blow type voltage (v.dc.) 5v 12v 15v 24v voltage accuracy 2% current (ma) max 3000 1250 1000 625 line regulation (ll-hl) (typ.) 0.5% load regulation (10-100%) (typ.) 1% maximum capacitive load (at 100-240 vac) 1100uf 200uf 200uf 47uf ripple & noise (typ.) 100mv (vp-p) 120mv (vp-p) 200mv (vp-p) 240mv (vp-p) output efficiency (at 230 vac) 78% 82% 81% 82% over power protection hicc up technique, auto-recovery over voltage protection zener diode clamp protection short circuit protection hiccup mode, indefinite (automatic recovery) isolation input-output (v.ac) 4000v operating temperature -40c?+70c (with derating) storage temperature -40c?+85c temperature coefficient 0.02%/c humidity 95% rh environment mtbf >450,000 h @ 25c (mil-hdbk-217f) dimension (l x w x h) 2.91 x 2.13 x 0.86 inches ( 74.1 x 54.1 x 21.8 mm ) tolerance ? 0.5 mm case material plastic resin (flammability to ul 94v-0) weight 114 g physical cooling method free air convection safety agency approvals ul/cul, ce emi (conducted & radiated emission) en 55022 class b emc ems (noise immunity) en 55024 note 1. ripple & noise are measured at 20mhz of bandwidth with 0.1uf & 47uf parallel capacitor. 2. it's necessary to add varistor 14s471k at l / n input side in parallel. 3. please refer to our pdf file "ac-dc applic ation" on our website: www.archcorp.com.tw key features ? switching power module for pcb mountable ? fully encapsulated plastic case ? universal input range 90-264vac ? <0.3w no load input power ? high average efficiency (25%, 50%, 75%, 100% load points) ? isolation class ii ? isolation 4kv ac ? ce, ul, approval ? 3-year product warranty
ver : a_4 update : 2015.11.27 ac-dc power module ancn series 15 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -2- mechanical dimension ( top view ) derating block diagram pin# single 1 ac in (n) 2 ac in (l) 3 -dc out 4 +dc out
ver : a_4 update : 2015.11.27 ac-dc power module ancn series 15 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -3- efficiency versus load ancn-5s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 77.0 79.8 80.8 80.1 79.8 load (%) 10 20 30 40 50 115v (%) 80.0 84.2 81.9 81.4 82.7 230v (%) 75.1 78.8 79.6 79.9 80.8 load (%) 60 70 80 90 100 115v (%) 82.1 80.9 80.3 80.2 79.4 230v (%) 81.1 79.7 81.4 80.1 79.3 50.00% 52.50% 55.00% 57.50% 60.00% 62.50% 65.00% 67.50% 70.00% 72.50% 75.00% 77.50% 80.00% 82.50% 85.00% 90 115 180 230 264 vin eff% 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff% ancn-12s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 80.5 82.4 83.7 84.6 83.3 load (%) 10 20 30 40 50 115v (%) 81.1 86.1 84.2 85.9 85.0 230v (%) 74.5 80.0 82.4 82.3 82.6 load (%) 60 70 80 90 100 115v (%) 85.0 83.9 83.1 83.3 82.6 230v (%) 83.6 80.2 81.7 83.8 84.8 50.00% 52.50% 55.00% 57.50% 60.00% 62.50% 65.00% 67.50% 70.00% 72.50% 75.00% 77.50% 80.00% 82.50% 85.00% 90 115 180 230 264 vin eff% 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff%
ver : a_4 update : 2015.11.27 ac-dc power module ancn series 15 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -4- efficiency versus load ancn-15s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 80.6 82.6 82.9 82.7 83.1 load (%) 10 20 30 40 50 115v (%) 85.9 83.3 85.7 84.7 85.4 230v (%) 74.0 78.5 79.9 81.7 82.3 load (%) 60 70 80 90 100 115v (%) 83.4 84.5 85.1 84.6 83.2 230v (%) 81.7 84.0 84.3 84.0 82.6 50.00% 52.50% 55.00% 57.50% 60.00% 62.50% 65.00% 67.50% 70.00% 72.50% 75.00% 77.50% 80.00% 82.50% 85.00% 90 115 180 230 264 vin eff% 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff% ANCN-24S vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 79.9 82.3 84.9 85.8 84.2 load (%) 10 20 30 40 50 115v (%) 79.5 86.3 84.6 86.5 85.4 230v (%) 70.1 80.0 79.5 80.7 81.7 load (%) 60 70 80 90 100 115v (%) 87.3 84.6 83.8 83.0 82.7 230v (%) 83.2 80.0 81.6 83.7 86.3 50.00% 52.50% 55.00% 57.50% 60.00% 62.50% 65.00% 67.50% 70.00% 72.50% 75.00% 77.50% 80.00% 82.50% 85.00% 90 115 180 230 264 vin eff% 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff%
|